| Architectural Glazing | | Brise Soleil | | Cladding | | (Automatic) Doors | | Louvres | | Rooflights / Skylights | | Security Glazing | | Smoke Curtains | | Smoke vents (SHEVs) | | Thermoplastics | | Windows (Aluminium & Composite) | | Offices | | Hospitality & Leisure | | Retail | | Mixed Use & Residential | | Transport | | Education | | Public Buildings | |
 |
 |
 |
 |
|
 |
|
| Daylight Products | Smoke & Heat Ventilation |
|
Smoke is potentially lethal, and it is well established that in the unfortunate event of a fire most deaths occur due to smoke inhalation rather than the victims actually being burned. The reduction of visibility in smoke also hampers evacuation and rescuing of disabled or injured occupants of buildings, as well as affecting fire-fighting operations.
The purpose of providing a smoke ventilation system is to allow the smoke and heat generated by the fire to exhaust to the atmosphere.
Williaam Cox Ireland Ltd. provide a complete range of high quality smoke and general day-to-day ventilation systems as part of our well-established range of COXDOME Building Products. COXDOME ventilation systems are suitable for almost every application, whether they are installed in a single storey industrial building, shopping centre or public building. The ventilators used for smoke and heat ventilation have been tested and conform to the requirements of Technical Guidance Document, Part B - 2006 -.
A control system forms an integral part of any smoke ventilation system and all COXDOME smoke ventilation systems operate on pneumatic or electric control. Click here for information on our electrical controls
We provide a supply, delivery, installation, commissioning and maintenance service for all our systems. |
Our range of SHEVs includes:
|
| |
|
|
COXDOME E-Type Combination Unit
|
|

|
| |
|
Specification
- Combined automatic smoke ventilator / access hatch
- Double skin polycarbonate dome mounted on an extruded aluminium frame and hinged to a secondary extruded aluminium sub-frame
- Sub-frame can be fitted with an insulated upstand or curb adaptor to suit a builder’s curb
- Can be driven open/closed via an automatic folding arm motor
- Manual opening switch, located on the internal sub-frame, allows the ventilator to be used as an access hatch, when opened
Applications
- Ideal in areas, where -besides ventilation- access to the roof is required
|
|
|
| Top |
|
|
COXDOME Eura
|
|

|
| |
|
Specification
- Natural smoke ventilator
- Dual functionality for day-to-day ventilation
- Automatic control
- Attractive painted or mill finish
- Pneumatic or electric opening mechanisms
- Louvres in polycarbonate, aluminium, laminated or other safety glasses
- Automatic wind and rain detection to close
- Provides natural daylight
Applications
- Usually commercial applications in flat or pitched
- Roofs, glazed structures or vertical wall openings
- Recommended for dry weather ventilation or with rain sensor
|
|
|
| Top |
|
|
COXDOME Eura R
|
|

|
| |
|
Specification
- Natural smoke ventilator
- Dual functionality for day to day ventilation
- Automatic control
- Attractive painted or mill finish
- Pneumatic or electric opening mechanisms
- Louvres in polycarbonate, aluminium, laminated or other safety glasses
- Automatic wind and rain detection to close
- Provides natural daylight
Applications
- Usually commercial applications in flat or pitched
- Roofs, glazed structures or vertical wall openings
- Recommend where ventilation is required when raining externally
|
|
|
| Top |
|
|
COXDOME
Duo Therma
|
|

|
| |
|
Specification
- Natural smoke ventilator
- Suitable for buildings with high standard of airtightness thermal nd acoustic insulation, and areas with high relative humidities
- Complete thermal separation and high standard of insulation
- Condensation forming can be practically precluded
Applications
- Very suitable for industrial buildings, offices, shopping centres and atria
|
|
|
| Top |
|
|
COXDOME
Mono Therma
|
|
| |
|
Specification
- Natural smoke ventilator - difference between Duo Therma is the single flap
- Suitable for buildings with high standard of airtightness, thermal and acoustic insulation, and areas with high relative humidities
- Complete thermal separation and high standard of insulation
- Condensation forming can be practically precluded
Applications
- Very suitable for industrial buildings, offices, shopping centres and atria
|
|
|
| Top |
|
|
COXDOME Inova
|
 |
| |
|
Specification
- Aesthetically venerable ventilation window designed for use in vertical applications
- The operating system is totally concealed from view (in closed position)
- Suitable for day-to-day and smoke ventilation
- Provides natural daylight
Applications
- Utility buildings, such as shopping centres, atria and public Buildings
- Suitable for use in façades
|
|
|
| Top |
|
|
COXDOME Ventria
|
|

|
| |
|
Specification
- Casement type ventilation
- Dual purpose: smoke and day-to-day ventilation
- Used in glass roof and wall construction
- Slimline framework and minimal depth
- Provides natural daylight
Applications
- Suitable for applications such as factory roofs, as well as aesthetically designed glass roof constructions
- Where concealed mechanisms are not required
|
|
|
| Top |
|
|
COXDOME Luma
|
|

|
| |
|
Specification
- Stylish designed ventilation window
- Suitable for both day-to-day and smoke ventilation
- In its closed position the operating system is totally concealed from view
- Provides natural daylight
Applications
- Utility buildings, such as shopping centres, atria and public buildings
- Ideal for use in aesthetically designed glass constructions
- Where concealed mechanisms are required
|
|
|
| Top |
|
|
COXDOME Estra
|
|
 |
| |
|
Specification
- Transparent louvre ventilator
- Suitable for providing a replacement air facility for smoke control systems or for day-to-day ventilation in natural ventilation systems
- Specifically designed for use in vertical applications
- Available with single glazed louvres and double glazed insulated louvres
- Provides natural daylight
Applications
- Ideally suited for use in predominantly glass structures
- An excellent choice for shopping centres, offices, atria and industrial buildings
|
|
|
| Top |
| |
|
| |
 |
 |
 |
 | |
|
Cloverhill Industrial Estate, Clondalkin, Dublin 22 Tel: +353 (0)1 4605400 Fax: +353 (0)1 4500481 Registered in Dublin, Ireland. No. 23587 |
Login | Sitemap |
| Copyright 2007 - Williaam Cox Ltd. All Rights Reserved. | | | |